Skip to content

Commit

Permalink
CHESTER: Update IAQ CO2 thresholds + LED
Browse files Browse the repository at this point in the history
Signed-off-by: hubmartin <[email protected]>
  • Loading branch information
hubmartin committed Apr 17, 2024
1 parent dc97c85 commit 3db4788
Showing 1 changed file with 35 additions and 1 deletion.
36 changes: 35 additions & 1 deletion chester/catalog-applications/chester-clime.md
Original file line number Diff line number Diff line change
Expand Up @@ -72,6 +72,7 @@ The catalog application **CHESTER Clime IAQ** measures:
- Motion detection with PIR sensor

Also, the application reports **push-button events** and provides **acoustic** and **optical feedback**.
The **button LED** color also **signalizes CO₂ concentration levels**.

The hardware of this application consists of the following ordering codes:

Expand Down Expand Up @@ -132,6 +133,8 @@ Firmware build shield options: `ctr_lte ctr_rtd_a`

When equipped with **CHESTER-S1**. The device also has a push button. When the button is pressed, the blue LED turns on for a second. Also, the **beep sound** is played from the integrated acoustic buzzer for audible confirmation of the push button press.

Also, the button on the optional **CHESTER-S1** by its color reports the state of the CO₂ by **green** (levels are ok), **orange** (warning) and **red** (alarm) thresholds. The button blinks shortly every 5 seconds when powered from a battery and it is permanently on when external power on X10 is applied. Threshold **levels** and **hysteresis** are **configurable**.

## Default Configuration

This is the default configuration (printed using the `app config show` command):
Expand Down Expand Up @@ -160,6 +163,21 @@ app config event-report-delay 1
app config event-report-rate 30
```

When equipped with **IAQ** (CHESTER-S1) you can change CO₂ thresholds and hysteresis which are signalized by button LED color:

```
app config iaq-led-thr-warning 800.0
app config iaq-led-thr-alarm 1600.0
app config iaq-led-hst 50.0
```

When equipped with **backup** (CHESTER-Z) or **external power** (CHESTER-X10), you can immediately report changes of the external power events:

```
app config backup-report-connected true
app config backup-report-disconnected true
```

## Specific Commands

:::info
Expand Down Expand Up @@ -233,7 +251,7 @@ When upgrading firmware from **v1.x.x** to version **v2.0.0 and newer** - it is

:::

The latest firmware is available in Catalog Applications [Firmware chapter](index.md#application-firmware).
The latest firmware is available in the Catalog Applications [Firmware chapter](index.md#application-firmware).

## Example JSON Message

Expand All @@ -243,6 +261,11 @@ In this example **JSON** you can see data from all three variants
- **CHESTER Clime IAQ** has its own `iaq_sensor` structure.
- **CHESTER Clime 1W** has its own `w1_thermometers` structure.
- **CHESTER Clime RTD** has its own `rtd_thermometers` structure.
- **CHESTER Clime** with **backup** option (CHESTER-Z or CHESTER-X10) has `backup` with external and internal voltages, state and events.

Backup **events** are:
* `connected`
* `disconnected`

Hygrometer **events** are:
* `alarm_hi_activated`
Expand Down Expand Up @@ -274,6 +297,17 @@ In each structure with the current configuration, there are six aggregated value
"voltage_load": 3.66,
"current_load": 36
},
"backup": {
"line_voltage": 24.01,
"batt_voltage": 4.09,
"state": "connected",
"events": [
{
"timestamp": 1668858942,
"type": "connected"
}
]
},
"network": {
"imei": 351358815180770,
"imsi": 901288910018982,
Expand Down