From 3d415188274716ef644a9a0043b8bfbb60e14f37 Mon Sep 17 00:00:00 2001 From: Stefan Wahren Date: Sat, 27 Jun 2020 16:00:53 +0200 Subject: [PATCH] Update XML reference output This updates the XML reference output after recent decoding changes. --- test/test-frames/EFE_Engelmann-WaterStar.xml | 2 +- test/test-frames/ELS_Elster-F96-Plus.xml | 4 ++-- test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.xml | 2 +- test/test-frames/abb_f95.xml | 4 ++-- test/test-frames/electricity-meter-1.xml | 2 +- test/test-frames/electricity-meter-2.xml | 2 +- test/test-frames/landis+gyr_ultraheat_t230.xml | 2 +- test/test-frames/siemens_water.xml | 2 +- test/test-frames/siemens_wfh21.xml | 2 +- 9 files changed, 11 insertions(+), 11 deletions(-) diff --git a/test/test-frames/EFE_Engelmann-WaterStar.xml b/test/test-frames/EFE_Engelmann-WaterStar.xml index 278bbc16..2c4a5363 100644 --- a/test/test-frames/EFE_Engelmann-WaterStar.xml +++ b/test/test-frames/EFE_Engelmann-WaterStar.xml @@ -6,7 +6,7 @@ EFE 0 Engelmann WaterStar - Hot water + Warm water (30-90°C) 12 27 0000 diff --git a/test/test-frames/ELS_Elster-F96-Plus.xml b/test/test-frames/ELS_Elster-F96-Plus.xml index 41b3e1f9..1bcedc83 100644 --- a/test/test-frames/ELS_Elster-F96-Plus.xml +++ b/test/test-frames/ELS_Elster-F96-Plus.xml @@ -48,14 +48,14 @@ Value during error state 0 Power (W) - 144445223 + DDDDEBBD Value during error state 0 Volume flow (m m^3/h) - 1445223 + DDEBBD diff --git a/test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.xml b/test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.xml index 05020492..c2492218 100644 --- a/test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.xml +++ b/test/test-frames/SLB_CF-Compact-Integral-MK-MaXX.xml @@ -58,7 +58,7 @@ Instantaneous value 0 Temperature Difference (1e-2 deg C) - 1500018 + F00018 diff --git a/test/test-frames/abb_f95.xml b/test/test-frames/abb_f95.xml index 4ddaadf9..2b14a587 100644 --- a/test/test-frames/abb_f95.xml +++ b/test/test-frames/abb_f95.xml @@ -30,14 +30,14 @@ Value during error state 0 Power (1e-1 W) - 144521543 + DDEBB4DD Value during error state 0 Volume flow (1e-4 m^3/h) - 1521543 + EBB4DD diff --git a/test/test-frames/electricity-meter-1.xml b/test/test-frames/electricity-meter-1.xml index 5a32f2ef..98069b99 100644 --- a/test/test-frames/electricity-meter-1.xml +++ b/test/test-frames/electricity-meter-1.xml @@ -2,7 +2,7 @@ - 5000244 + 500023E SBC 18 diff --git a/test/test-frames/electricity-meter-2.xml b/test/test-frames/electricity-meter-2.xml index d5a1c478..810c9c1a 100644 --- a/test/test-frames/electricity-meter-2.xml +++ b/test/test-frames/electricity-meter-2.xml @@ -2,7 +2,7 @@ - 5000345 + 50002E5 @@@ 18 diff --git a/test/test-frames/landis+gyr_ultraheat_t230.xml b/test/test-frames/landis+gyr_ultraheat_t230.xml index 1bd0ef3a..ea3a8791 100644 --- a/test/test-frames/landis+gyr_ultraheat_t230.xml +++ b/test/test-frames/landis+gyr_ultraheat_t230.xml @@ -72,7 +72,7 @@ Instantaneous value 0 Temperature Difference (1e-1 deg C) - 1500002 + F00002 diff --git a/test/test-frames/siemens_water.xml b/test/test-frames/siemens_water.xml index a8ec54af..8cc6c65a 100644 --- a/test/test-frames/siemens_water.xml +++ b/test/test-frames/siemens_water.xml @@ -6,7 +6,7 @@ LSE 153 Siemens WFH21 - Hot water + Warm water (30-90°C) 235 00 0000 diff --git a/test/test-frames/siemens_wfh21.xml b/test/test-frames/siemens_wfh21.xml index 8f3b7901..7bff369f 100644 --- a/test/test-frames/siemens_wfh21.xml +++ b/test/test-frames/siemens_wfh21.xml @@ -6,7 +6,7 @@ LSE 153 Siemens WFH21 - Hot water + Warm water (30-90°C) 218 00 0000