Currently used pipes (Buildings.Fluid.FixedResistances.Pipe) calculate pipe diameter based on nominal mass flow rate and the assumption that the fluid velocity at nominal flow is 0.15 m/s. However, data from pipe manufacturers shows that the pipe velocity is higher in DH context and varies with the pipe diameter. I suggest to use the actual pipe diameter as an input instead, and if needed the nominal mass flow rate as well.

@bramvdh91 bramvdh91 self-assigned this Jun 29, 2015
@bramvdh91 bramvdh91 added this to the Diameter input milestone Jun 30, 2015