function V0 = getV0(bus, gen, type_initialguess, V0)
%GETV0 Get initial voltage profile for power flow calculation.
% Note: The pv bus voltage will remain at the given value even for
% flat start.
% type_initialguess: 1 - initial guess from case data
% 2 - flat start
% 3 - from input
% MATPOWER
% Copyright (c) 2009-2016, Power Systems Engineering Research Center (PSERC)
% by Rui Bo
%
% This file is part of MATPOWER/mx-se.
% Covered by the 3-clause BSD License (see LICENSE file for details).
% See https://github.com/MATPOWER/mx-se/ for more info.
%% define named indices into bus, gen, branch matrices
[PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus;
[F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, ...
RATE_C, TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST] = idx_brch;
[GEN_BUS, PG, QG, QMAX, QMIN, VG, MBASE, ...
GEN_STATUS, PMAX, PMIN, MU_PMAX, MU_PMIN, MU_QMAX, MU_QMIN] = idx_gen;
%% generator info
on = find(gen(:, GEN_STATUS) > 0); %% which generators are on?
gbus = gen(on, GEN_BUS); %% what buses are they at?
if type_initialguess == 1 % using previous value in case data
% NOTE: angle is in degree in case data, but in radians in pf solver,
% so conversion from degree to radians is needed here
V0 = bus(:, VM) .* exp(1j * pi/180 * bus(:, VA));
elseif type_initialguess == 2 % using flat start
V0 = ones(size(bus, 1), 1);
elseif type_initialguess == 3 % using given initial voltage
V0 = V0;
else
fprintf('Error: unknow ''type_initialguess''.\n');
pause
end
% set the voltages of PV bus and reference bus into the initial guess
V0(gbus) = gen(on, VG) ./ abs(V0(gbus)).* V0(gbus);