You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Yesterday I ran into an issue with my Otter Iron PRO: the tip became glowing red hot! What happened is that I set its temperature to 400°C, and as the temperature readout was saturating at ~390°C the controller sent full power (65W) to the tip. What surprised me the most is that after letting the tip cool off, it still works (if I set the temp to < 390°C).
I'm using Jabe tips, not the JBC ones so that could explain the issue with the temp readout.
Has anyone here tried to run their iron at more than 390°C?
The text was updated successfully, but these errors were encountered:
To my biggest surprise, the tip is still functional! I was able to finish my VQFN bodge job, but I'm going to order a new one anyway just to be sure.
Yesterday I received some other kind of C245 tips. I still have the 390°C saturation issue, plus the temperature is super unstable (like ±20°C). I will try to investigate on my scope what's being sent to the ADC.
Please share the results! However I highly suspect my shitty control loop for being the cause. You might also want to try to tune it for better results
Hi everyone,
Yesterday I ran into an issue with my Otter Iron PRO: the tip became glowing red hot! What happened is that I set its temperature to 400°C, and as the temperature readout was saturating at ~390°C the controller sent full power (65W) to the tip. What surprised me the most is that after letting the tip cool off, it still works (if I set the temp to < 390°C).
I'm using Jabe tips, not the JBC ones so that could explain the issue with the temp readout.
Has anyone here tried to run their iron at more than 390°C?
The text was updated successfully, but these errors were encountered: